Home    Prefilters    Single-layer Cartridge Filter(MCE 0.2μm)
4

Single-layer Cartridge Filter(MCE 0.2μm)

Product Introduction

Alioth Aligard® MHF Single-layer Cartridge Filter is made from mixed cellulose ester. It has a nominal filtration accuracy of 0.2 μm, a sturdy structure and stable material. It can efficiently retain pollutants, effectively remove particles and colloidal contaminants, block no important active ingredients, protect downstream filtration equipment, and prevent premature clogging.

 

Key Features and Benefits

  • Fast flow rate
  • High capacity
  • No fiber release
  • Can withstand multiple cycles of high-temperature sterilization

 

Typical Applications

  • Pre-filtration of culture media and buffer solutions
  • Pre-filtration of LVP/SVP
  • Pre-filtration of blood products
  • Pre-filtration for column protection, etc.

 

Typical Flow Characteristics

 

 

Product Specifications

  10 inch 20 inch 30 inch

Dimensions

Diameter
Maximum Length

 

69 mm
320 mm

 

69 mm
560 mm

 

69 mm
800 mm

Filtration Area 0.68 m2 1.32 m2 1.98 m2
Pore Size 0.2 μm
Materials of Construction

Filter membrane:Mixed Cellulose Ester                     

Supporting Layer: Polypropylene (PP)
O-rings of capsules vent: Silicone                             

Liner / Cartridge body: Polypropylene (PP)
End caps: Polypropylene/ Polycarbonate (PP/PC)

Maximum Differential
Pressure
Forward: 5 bar ( 72.5 psi ) @ 25℃ / 1.5 bar ( 21.75 psi ) @ 80℃ / Reverse: 2 bar ( 29 psi ) @ 25℃
Sterilization Parameters 121℃, 30 minutes, 5 cycles of high-pressure sterilizations or 5 cycles of sterilization in place
Extractable Water: ~20 mg / 10 inch
Ethanol: water ( 50:50 ): ~55 mg / 10 inch
Biological Safety All the construction components of this cartridge comply with the requirements for biological safety of Class VI plastics in current USP < 88 >
Indirect Food Additive The primary construction components of this cartridge comply with the reguirements for food contact materials as stipulated in EU 1935 / 2004 / EC and FDA 21 CFR 177-182
Cleanliness Cleanliness meets the requirements for nonfiber releasing filter as specified in FDA 21 CFR 211.72 and 210.3 (b) (5) (6), and the level of insoluble particles in rinsing liquid meets the
requirements of USP < 788 >
Endotoxin The endotoxin level of cartridge rinsing liquid is < 0.25 EU/mL as indicated by gel method, which complies with the requirements of USP < 85 >
Integrity Each filter has passed the integrity test
TOC / Conductivity TOC < 0.5 mg/L, Conductivity < 1.3 μS/cm
Manufacturing environment Manufactured in conformance with cGMP

 

Ordering Information

 

For further information, please contact us and Alioth technical team will provide a comprehensive service for your filtration process.